[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fBf_uyPaVXVwGijfheu8vzxKRUSqLTkUaeWXItnhpmqA":3},{"article":4,"iocs":44},{"id":5,"title":6,"slug":7,"summary":8,"ai_summary":9,"brief":10,"full_text":11,"url":12,"image_url":13,"published_at":14,"ingested_at":15,"relevance_score":16,"entities":17,"category_id":27,"category":28,"article_tags":31},"c2d761f6-65fd-4969-a6f2-69b611be9dab","Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module","mitsubishi-electric-co-s-melsec-iq-f-series-fx5-enet-ip-ethernet-module-de52f7","View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP vers:all\u002F* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. View CVE Details Affected Products Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP: vers:all\u002F* Product Status: known_affected Remediations No fix planned There are no plans to release fixed version for MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP. For customers of MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP, refer to the Mitsubishi Electric security advisory \"https:\u002F\u002Fwww.mitsubishielectric.com\u002Fpsirt\u002Fvulnerability\u002Fpdf\u002F2026-003_en.pdf\", and take the actions described there. https:\u002F\u002Fwww.mitsubishielectric.com\u002Fpsirt\u002Fvulnerability\u002Fpdf\u002F2026-003_en.pdf Mitigation For customers, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to \"13.1 IP Filter Function\" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link \"https:\u002F\u002Fwww.mitsubishielectric.com\u002Ffa\u002Fdownload\u002Findex.html.\" https:\u002F\u002Fwww.mitsubishielectric.com\u002Ffa\u002Fdownload\u002Findex.html Mitigation For customers, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-440 Expected Behavior Violation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:N\u002FI:N\u002FA:H 4.0 8.7 HIGH CVSS:4.0\u002FAV:N\u002FAC:L\u002FAT:N\u002FPR:N\u002FUI:N\u002FVC:N\u002FVI:N\u002FVA:H\u002FSC:N\u002FSI:N\u002FSA:N Acknowledgments Mitsubishi Electric discovering this vulnerability Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and\u002For systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-003 advisory Legal Notice and Terms of Use","A denial-of-service vulnerability (CVE-2026-8806) has been identified in Mitsubishi Electric's MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module. Attackers can exploit this by sending a high volume of communication packets, overwhelming the device and causing its communication function to stop. No fix is planned, and users are advised to implement network segmentation, firewalls, VPNs, and IP filtering.","Mitsubishi Electric MELSEC iQ-F Ethernet module vulnerable to DoS attacks.","ICS Advisory Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module Release DateJune 18, 2026 Alert CodeICSA-26-169-06 Related topics: Industrial Control System Vulnerabilities , Industrial Control Systems View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP vers:all\u002F* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and causing the communication function to stop. View CVE Details Affected Products Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module Vendor:Mitsubishi Electric Product Version:Mitsubishi Electric MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP: vers:all\u002F* Product Status:known_affected Remediations No fix plannedThere are no plans to release fixed version for MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP. For customers of MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module FX5-ENET\u002FIP, refer to the Mitsubishi Electric security advisory \"https:\u002F\u002Fwww.mitsubishielectric.com\u002Fpsirt\u002Fvulnerability\u002Fpdf\u002F2026-003_en.pdf\", and take the actions described there.https:\u002F\u002Fwww.mitsubishielectric.com\u002Fpsirt\u002Fvulnerability\u002Fpdf\u002F2026-003_en.pdf MitigationFor customers, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. MitigationFor customers, Mitsubishi Electric recommends using the affected product within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. MitigationFor customers, Mitsubishi Electric recommends using the IP filter function of the affected product to block access from untrusted hosts and minimize the risk of exploiting this vulnerability. For details on the IP filter function, refer to \"13.1 IP Filter Function\" in the MELSEC iQ-F FX5 User's Manual (Communication) which can be downloaded from the link \"https:\u002F\u002Fwww.mitsubishielectric.com\u002Ffa\u002Fdownload\u002Findex.html.\"https:\u002F\u002Fwww.mitsubishielectric.com\u002Ffa\u002Fdownload\u002Findex.html MitigationFor customers, Mitsubishi Electric recommends restricting physical access to the affected product, as well as to PCs and network devices to which it is connected, to minimize the risk of exploiting this vulnerability. MitigationFor customers, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-440 Expected Behavior Violation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:N\u002FI:N\u002FA:H 4.0 8.7 HIGH CVSS:4.0\u002FAV:N\u002FAC:L\u002FAT:N\u002FPR:N\u002FUI:N\u002FVC:N\u002FVI:N\u002FVA:H\u002FSC:N\u002FSI:N\u002FSA:N Acknowledgments Mitsubishi Electric discovering this vulnerability Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and\u002For systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-003 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-18 Date Revision Summary 2026-06-18 1 Initial Publication 2026-06-18 2 Initial CISA Republication of Mitsubishi Electric 2026-003 advisory Legal Notice and Terms of Use This product is provided subject to this Notification and this Privacy & Use policy. Vendor Mitsubishi Electric Tags Sector: Critical Manufacturing Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems Please share your thoughts We recently updated our anonymous product survey; we welcome your feedback. Related Advisories Jun 18, 2026 ICS Advisory | ICSA-26-169-02 AzeoTech DAQFactory Jun 18, 2026 ICS Advisory | ICSA-26-169-01 AVer PTC cameras Jun 18, 2026 ICS Advisory | ICSA-26-169-07 Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products Jun 18, 2026 ICS Advisory | ICSA-26-169-04 Schneider Electric EasyLogic T150 and Saitel DP","https:\u002F\u002Fwww.cisa.gov\u002Fnews-events\u002Fics-advisories\u002Ficsa-26-169-06",null,"2026-06-18T12:00:00+00:00","2026-06-18T18:00:17.748291+00:00",8,[18,21,24],{"name":19,"type":20},"MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module","product",{"name":22,"type":23},"Mitsubishi Electric","vendor",{"name":25,"type":26},"Ethernet","technology","80544778-fabb-4dcd-aa35-17492e5dcf4f",{"id":27,"icon":13,"name":29,"slug":30},"Vulnerabilities","vulnerabilities",[32,34,39],{"category":33},{"id":27,"icon":13,"name":29,"slug":30},{"category":35},{"id":36,"icon":13,"name":37,"slug":38},"d6f63bb8-0801-486a-be7f-171400700454","IoT\u002FOT","iot-ot",{"category":40},{"id":41,"icon":13,"name":42,"slug":43},"e7b231c8-5f79-4465-8d38-1ef13aea5a14","Threat Intelligence","threat-intelligence",[45],{"type":46,"value":47,"context":48},"cve","CVE-2026-8806","Denial-of-service vulnerability in MELSEC iQ-F Series FX5-ENET\u002FIP Ethernet Module"]