[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fwjCgr9Aa9MCxvOsmNUnKaFfXPEAEEwxF51uvMFw4dGI":3},{"article":4,"iocs":40},{"id":5,"title":6,"slug":7,"summary":8,"ai_summary":9,"brief":10,"full_text":11,"url":12,"image_url":13,"published_at":14,"ingested_at":15,"relevance_score":16,"entities":17,"category_id":23,"category":24,"article_tags":27},"052ea76e-e6b9-41f7-a93f-61e7721eef0c","Orthanc DICOM Server","orthanc-dicom-server-9eb9ce","View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash of the Orthanc process and a denial-of-service condition. The following versions of Orthanc DICOM Server are affected: Orthanc DICOM Server \u003C1.13.0. (CVE-2026-87020) CVSS Vendor Equipment Vulnerabilities v3 8.1 Orthanc Orthanc DICOM Server Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Healthcare and Public Health Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Belgium Vulnerabilities Expand All + CVE-2026-87020 An integer overflow in a specified pitch and buffer-size computation leads to a heap out-of-bounds write when Orthanc decodes an attacker-supplied PNG. View CVE Details Affected Products Orthanc DICOM Server Vendor: Orthanc Product Version: Orthanc Orthanc DICOM Server: \u003C1.13.0. Product Status: known_affected Remediations Mitigation Orthanc recommends users update to v1.13.0. https:\u002F\u002Forthanc.uclouvain.be\u002Fdownloads\u002Findex.html Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:L\u002FUI:N\u002FS:U\u002FC:N\u002FI:H\u002FA:H 4.0 7.2 HIGH CVSS:4.0\u002FAV:N\u002FAC:L\u002FAT:N\u002FPR:L\u002FUI:N\u002FVC:N\u002FVI:H\u002FVA:H\u002FSC:N\u002FSI:N\u002FSA:N Acknowledgments Andrej Tomci reported this vulnerability to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and\u002For systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov\u002Fics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov\u002Fics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-10 Date Revision Summary 2026-09-10 1 Initial Publication Legal Notice and Terms of Use","A critical vulnerability, CVE-2026-87020, has been identified in Orthanc DICOM Server versions prior to 1.13.0. This flaw allows an authenticated remote attacker to cause a denial-of-service condition by triggering a heap out-of-bounds write when processing specially crafted PNG or JPEG images. The vulnerability is particularly concerning as Orthanc DICOM Server is deployed in the Healthcare and Public Health sectors worldwide.","Orthanc DICOM Server vulnerability CVE-2026-87020 allows DoS via heap overflow.","ICS Medical Advisory Orthanc DICOM Server Release DateSeptember 10, 2026 Alert CodeICSMA-26-253-02 Related topics: Industrial Control System Vulnerabilities , Industrial Control Systems View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash of the Orthanc process and a denial-of-service condition. The following versions of Orthanc DICOM Server are affected: Orthanc DICOM Server \u003C1.13.0. (CVE-2026-87020) CVSS Vendor Equipment Vulnerabilities v3 8.1 Orthanc Orthanc DICOM Server Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Healthcare and Public Health Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Belgium Vulnerabilities Expand All + CVE-2026-87020 An integer overflow in a specified pitch and buffer-size computation leads to a heap out-of-bounds write when Orthanc decodes an attacker-supplied PNG. View CVE Details Affected Products Orthanc DICOM Server Vendor:Orthanc Product Version:Orthanc Orthanc DICOM Server: \u003C1.13.0. Product Status:known_affected Remediations MitigationOrthanc recommends users update to v1.13.0. https:\u002F\u002Forthanc.uclouvain.be\u002Fdownloads\u002Findex.html Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:L\u002FUI:N\u002FS:U\u002FC:N\u002FI:H\u002FA:H 4.0 7.2 HIGH CVSS:4.0\u002FAV:N\u002FAC:L\u002FAT:N\u002FPR:L\u002FUI:N\u002FVC:N\u002FVI:H\u002FVA:H\u002FSC:N\u002FSI:N\u002FSA:N Acknowledgments Andrej Tomci reported this vulnerability to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and\u002For systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov\u002Fics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov\u002Fics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-10 Date Revision Summary 2026-09-10 1 Initial Publication Legal Notice and Terms of Use This product is provided subject to this Notification and this Privacy & Use policy. Tags Sector: Healthcare and Public Health Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems Please share your thoughts We recently updated our anonymous product survey; we welcome your feedback. Related Advisories Sep 10, 2026 ICS Medical Advisory | ICSMA-26-253-01 NextGen Healthcare Mirth Connect Aug 13, 2026 ICS Medical Advisory | ICSMA-26-225-01 Flow Neuroscience FL-100 Aug 11, 2026 ICS Medical Advisory | ICSMA-26-223-01 Mira Hormone Monitor, Mira Android App Aug 11, 2026 ICS Medical Advisory | ICSMA-26-223-02 Pulsetto Vagus Nerve Stimulator","https:\u002F\u002Fwww.cisa.gov\u002Fnews-events\u002Fics-medical-advisories\u002Ficsma-26-253-02",null,"2026-09-10T12:00:00+00:00","2026-09-10T16:00:07.794491+00:00",8,[18,20],{"name":6,"type":19},"product",{"name":21,"type":22},"Orthanc","vendor","80544778-fabb-4dcd-aa35-17492e5dcf4f",{"id":23,"icon":13,"name":25,"slug":26},"Vulnerabilities","vulnerabilities",[28,30,35],{"category":29},{"id":23,"icon":13,"name":25,"slug":26},{"category":31},{"id":32,"icon":13,"name":33,"slug":34},"d6f63bb8-0801-486a-be7f-171400700454","IoT\u002FOT","iot-ot",{"category":36},{"id":37,"icon":13,"name":38,"slug":39},"e7b231c8-5f79-4465-8d38-1ef13aea5a14","Threat Intelligence","threat-intelligence",[41],{"type":42,"value":43,"context":44},"cve","CVE-2026-87020","Integer overflow leading to heap out-of-bounds write in Orthanc DICOM Server"]