[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fxIdFBdk6MtNdwv2HmZDMMB0Dma2oilcgr956Bf4lP3Y":3},{"article":4,"iocs":44},{"id":5,"title":6,"slug":7,"summary":8,"ai_summary":9,"brief":10,"full_text":11,"url":12,"image_url":13,"published_at":14,"ingested_at":15,"relevance_score":16,"entities":17,"category_id":27,"category":28,"article_tags":31},"94e8cad8-1061-4996-8d15-f30860ebf8fa","Siemens Teamcenter","siemens-teamcenter-affe17","View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (\u002Fauth\u002F) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2412 vers:intdot\u002F\u003C2412.0013 (CVE-2026-58113) Teamcenter V2506 vers:intdot\u002F\u003C2506.0010 (CVE-2026-58113) Teamcenter V2512 vers:intdot\u002F\u003C2512.2607 (CVE-2026-58113) Teamcenter V2606 vers:intdot\u002F\u003C2606.2607 (CVE-2026-58113) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens Teamcenter Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-58113 Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (\u002Fauth\u002F endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session. View CVE Details Affected Products Siemens Teamcenter Vendor: Siemens Product Version: Teamcenter V2412 \u003C V2412.0013, Teamcenter V2506 \u003C V2506.0010, Teamcenter V2512 \u003C V2512.2607, Teamcenter V2606 \u003C V2606.2607 Product Status: known_affected Remediations Vendor fix Update to V2412.0013 or later version https:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fix Update to V2506.0010 or later version https:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fix Update to V2512.2607 or later version https:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fix Update to V2606.2607 or later version https:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:R\u002FS:C\u002FC:L\u002FI:L\u002FA:N Acknowledgments Enzo Alvarez from Bishop Fox reported this vulnerability to Siemens. General Recommendations As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https:\u002F\u002Fwww.siemens.com\u002Findustrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https:\u002F\u002Fwww.siemens.com\u002Fcert\u002Fadvisories Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage For more information see the associated Siemens security advisory SSA-157465 in HTML and CSAF. Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https:\u002F\u002Fwww.siemens.com\u002Fproductcert\u002Fterms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and\u002For systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-157465 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-08 Date Revision Summary 2026-09-08 1 Publication Date 2026-09-15 2 Initial CISA Republication of Siemens ProductCERT SSA-157465 advisory Legal Notice and Terms of Use","A reflected cross-site scripting (XSS) vulnerability has been identified in Siemens Teamcenter's authentication redirect flow. This flaw allows unauthenticated remote attackers to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation could lead to unauthorized data access or actions within the victim's Teamcenter session. Siemens has released updated versions to address this vulnerability.","Siemens Teamcenter has a reflected XSS vulnerability in its authentication redirect flow.","ICS Advisory Siemens Teamcenter Release DateSeptember 15, 2026 Alert CodeICSA-26-258-07 Related topics: Industrial Control System Vulnerabilities , Industrial Control Systems View CSAF Summary A reflected cross site scripting vulnerability in the authentication redirect flow (\u002Fauth\u002F) of Teamcenter allows an unauthenticated remote attacker to inject JavaScript into an authenticated user's session by crafting a malicious URL. Successful exploitation may enable the attacker to read data or perform actions within the victim's Teamcenter session. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2412 vers:intdot\u002F\u003C2412.0013 (CVE-2026-58113) Teamcenter V2506 vers:intdot\u002F\u003C2506.0010 (CVE-2026-58113) Teamcenter V2512 vers:intdot\u002F\u003C2512.2607 (CVE-2026-58113) Teamcenter V2606 vers:intdot\u002F\u003C2606.2607 (CVE-2026-58113) CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens Teamcenter Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries\u002FAreas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-58113 Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (\u002Fauth\u002F endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session. View CVE Details Affected Products Siemens Teamcenter Vendor:Siemens Product Version:Teamcenter V2412 \u003C V2412.0013, Teamcenter V2506 \u003C V2506.0010, Teamcenter V2512 \u003C V2512.2607, Teamcenter V2606 \u003C V2606.2607 Product Status:known_affected Remediations Vendor fixUpdate to V2412.0013 or later versionhttps:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fixUpdate to V2506.0010 or later versionhttps:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fixUpdate to V2512.2607 or later versionhttps:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Vendor fixUpdate to V2606.2607 or later versionhttps:\u002F\u002Fsupport.sw.siemens.com\u002Fproduct\u002F282219420\u002F Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:R\u002FS:C\u002FC:L\u002FI:L\u002FA:N Acknowledgments Enzo Alvarez from Bishop Fox reported this vulnerability to Siemens. General Recommendations As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https:\u002F\u002Fwww.siemens.com\u002Findustrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https:\u002F\u002Fwww.siemens.com\u002Fcert\u002Fadvisories Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage For more information see the associated Siemens security advisory SSA-157465 in HTML and CSAF. Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https:\u002F\u002Fwww.siemens.com\u002Fproductcert\u002Fterms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https:\u002F\u002Fwww.cisa.gov\u002Fnotification) and this Privacy & Use policy (https:\u002F\u002Fwww.cisa.gov\u002Fprivacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and\u002For systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-157465 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-08 Date Revision Summary 2026-09-08 1 Publication Date 2026-09-15 2 Initial CISA Republication of Siemens ProductCERT SSA-157465 advisory Legal Notice and Terms of Use This product is provided subject to this Notification and this Privacy & Use policy. Vendor Siemens Tags Sector: Critical Manufacturing Sector, Information Technology Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems Please share your thoughts We recently updated our anonymous product survey; we welcome your feedback. Related Advisories Sep 15, 2026 ICS Advisory | ICSA-26-258-03 mySCADA myPRO Manager Sep 15, 2026 ICS Advisory | ICSA-26-258-02 Wärtsilä FOS-Onboard Sep 15, 2026 ICS Advisory | ICSA-26-258-08 CareCam CM2507 Sep 15, 2026 ICS Advisory | ICSA-26-258-01 Digital Watchdog VMAX DVR and NVR Product Lineups","https:\u002F\u002Fwww.cisa.gov\u002Fnews-events\u002Fics-advisories\u002Ficsa-26-258-07",null,"2026-09-15T12:00:00+00:00","2026-09-15T16:00:37.813532+00:00",8,[18,21,24],{"name":19,"type":20},"Teamcenter","product",{"name":22,"type":23},"Siemens","vendor",{"name":25,"type":26},"Cross-site Scripting","technology","80544778-fabb-4dcd-aa35-17492e5dcf4f",{"id":27,"icon":13,"name":29,"slug":30},"Vulnerabilities","vulnerabilities",[32,37,39],{"category":33},{"id":34,"icon":13,"name":35,"slug":36},"26b0b636-0e31-4db1-bffb-61bdf9f20a58","Supply Chain","supply-chain",{"category":38},{"id":27,"icon":13,"name":29,"slug":30},{"category":40},{"id":41,"icon":13,"name":42,"slug":43},"d6f63bb8-0801-486a-be7f-171400700454","IoT\u002FOT","iot-ot",[45],{"type":46,"value":47,"context":48},"cve","CVE-2026-58113","Reflected XSS vulnerability in Siemens Teamcenter"]