ABB PCM600 path traversal vulnerability allows arbitrary code execution via crafted messages.
Summary
CISA disclosed CVE-2018-1002208, a path traversal vulnerability in ABB PCM600 versions 1.5 through 2.13 that allows local attackers with low privileges to execute arbitrary code by sending specially crafted messages. The flaw exists in the bundled SharpZip.dll library and affects critical manufacturing infrastructure worldwide. ABB released version 2.14 as a fix, though RE_630 protection relays are incompatible with this patched version.
Full text
ICS Advisory ABB PCM600 Release DateApril 30, 2026 Alert CodeICSA-26-120-02 Related topics: Industrial Control System Vulnerabilities, Industrial Control Systems View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send specially crafted messages to the system node resulting in execution of arbitrary code. The following versions of ABB PCM600 are affected: PCM600 >=1.5|<=2.13 CVSS Vendor Equipment Vulnerabilities v3 4.4 ABB ABB PCM600 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2018-1002208 A vulnerability exists in the SharpZip.dll included in the product versions listed above. An attacker could exploit vulnerability by providing a specially crafted message to the system node, causing insertion, and running of arbitrary code. View CVE Details Affected Products ABB PCM600 Vendor:ABB Product Version:ABB PCM600: >=1.5|<=2.13 Product Status:known_affected Remediations Vendor fixThe problem is corrected in the following product version: ABB Protection and control IED manager PCM600 version 2.14. ABB recommends that customers apply the update at earliest convenience. Vendor fixNote: RE_630 protection relays are not compatible with PCM600 version 2.14. When using earlier PCM600 versions with RE_630, the known vulnerability must be mitigated through system-level defenses. For mitigation guidance, refer to the General Security Recommendations. Vendor fixThe following product versions have been fixed: Protection and Control IED manager PCM600 2.14 is a fixed version for CVE-2018-1002208 MitigationFor more information see the associated ABB PSIRT security advisory 2NGA002813 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/2nga002813.json).https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch MitigationFor more information see the associated ABB PSIRT security advisory 2NGA002813 ABB CYBERSECURITY ADVISORY - PDF version (https://search.abb.com/library/Download.aspx?DocumentID=2NGA002813&LanguageCode=en&DocumentPartId=pdf&Action=Launch), ABB CYBERSECURITY ADVISORY - CSAF version (https://psirt.abb.com/csaf/2025/2nga002813.json).https://psirt.abb.com/csaf/2025/2nga002813.json Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N Acknowledgments ABB PSIRT reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-04-30 Date Revision Summary 2026-04-30 1 Initial Republication of ABB PSIRT 2NGA002813 Legal Notice and Terms of Use This product is provided subject to this Notification and this Privacy & Use policy. Vendor ABB Tags Sector: Critical Manufacturing Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems Please share your thoughts We recently updated our anonymous product survey; we welcome your feedback. Related Advisories Apr 30, 2026 ICS Advisory | ICSA-26-120-06 ABB Ability Symphony Plus Engineering Apr 30, 2026 ICS Advisory | ICSA-26-120-05 ABB AWIN Gateways Apr 30, 2026 ICS Advisory | ICSA-26-120-04 ABB Ability OPTIMAX Apr 30, 2026 ICS Advisory | ICSA-26-120-03 ABB Edgenius Management Portal
Indicators of Compromise
- cve — CVE-2018-1002208