Siemens Siveillance Control
Siemens Siveillance Control vulnerability allows arbitrary file upload and root access.
Summary
A critical vulnerability (CVE-2026-50093) has been identified in Siemens Siveillance Control and Siveillance Control Pro, specifically within the Open Interface Services (OIS) web module. This flaw enables attackers to upload arbitrary files, potentially leading to unauthorized root-level access on the OIS server. Siemens has released patches and urges users to update to the latest versions to mitigate the risk of full system compromise.
Full text
ICS Advisory Siemens Siveillance Control Release DateSeptember 22, 2026 Alert CodeICSA-26-265-03 Related topics: Industrial Control System Vulnerabilities , Industrial Control Systems View CSAF Summary A vulnerability has been identified in the Open Interface Services (OIS) web module affecting Siveillance Control and Siveillance Control Pro (versions OIS 3.x.y and OIS 4.x.y) . This vulnerability allows an attacker to upload arbitrary files, which can lead to unauthorized root-level access on the OIS server. Siemens has released patches and updates for Siveillance OIS to apply to the products that incorporate the OIS service, and recommends to update to the latest versions. The following versions of Siemens Siveillance Control are affected: Siveillance Control Pro V3.0 vers:intdot/<3.0.12.2173 (CVE-2026-50093) Siveillance Control Pro V4.0 vers:intdot/<4.0.9.2178 (CVE-2026-50093) Siveillance Control V3.0 vers:intdot/<3.0.22.2177 (CVE-2026-50093) Siveillance Control V4.0 vers:intdot/<4.0.11.2177 (CVE-2026-50093) CVSS Vendor Equipment Vulnerabilities v3 9 Siemens Siemens Siveillance Control Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Critical Manufacturing, Communications, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50093 A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment. View CVE Details Affected Products Siemens Siveillance Control Vendor:Siemens Product Version:Siveillance Control Pro V3.0 < V3.0.12.2173, Siveillance Control Pro V4.0 < V4.0.9.2178, Siveillance Control V3.0 < V3.0.22.2177, Siveillance Control V4.0 < V4.0.11.2177 Product Status:known_affected Remediations Vendor fixUpdate to V3.0.12.2173 or later versionhttps://support.industry.siemens.com/cs/ww/en/view/110004860/ Vendor fixUpdate to V3.0.22.2177 or later versionhttps://support.industry.siemens.com/cs/ww/en/view/110004859/ Vendor fixUpdate to V4.0.11.2177 or later versionhttps://support.industry.siemens.com/cs/ww/en/view/110004859/ Vendor fixUpdate to V4.0.9.2178 or later versionhttps://support.industry.siemens.com/cs/ww/en/view/110004860/ Vendor fixFor more information see the associated Siemens security advisory SSA-254516: Arbitrary File Upload in OIS Web Module - CSAF Version, SSA-254516: Arbitrary File Upload in OIS Web Module - HTML Version. Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment. Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-254516 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-08 Date Revision Summary 2026-09-08 1 Publication Date 2026-09-22 2 Initial CISA Republication of Siemens ProductCERT SSA-254516 advisory Legal Notice and Terms of Use This product is provided subject to this Notification and this Privacy & Use policy. Vendor Siemens Tags Sector: Commercial Facilities Sector, Communications Sector, Critical Manufacturing Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems Please share your thoughts We recently updated our anonymous product survey; we welcome your feedback. Related Advisories Sep 22, 2026 ICS Advisory | ICSA-26-265-09 OpenPLC Runtime v3 Sep 22, 2026 ICS Advisory | ICSA-26-265-02 lwIP (Lightweight IP) Sep 22, 2026 ICS Advisory | ICSA-26-265-04 Siemens SIPLUS and SIMATIC Products Sep 22, 2026 ICS Advisory | ICSA-26-265-01 lwIP TCP/IP Stack MQTT Client Application
Indicators of Compromise
- cve — CVE-2026-50093